ROSCO LABORATORIES -- ROSCO FOG FLUID -- 6850-00F005880
=====================  Product Identification  =====================

Product ID:ROSCO FOG FLUID
MSDS Date:07/01/1993
FSC:6850
NIIN:00F005880
=== Responsible Party ===
Company Name:ROSCO LABORATORIES
Address:36 BUSH AVE
City:PORT CHESTER
State:NY
ZIP:10573-3904
Country:US
Info Phone Num:914-937-1300 EST/213-462-2233 PST
Emergency Phone Num:914-938-9169/203-327-3244 (N & WE)
Preparer's Name:STAN MILLER
CAGE:86807
=== Contractor Identification ===
Company Name:ROSCO LABORATORIES INC (FORMER LOCATION: PORT CHESTER, NY)
Address:52 HARBOR VIEW AVE
Box:City:STAMFORD
State:CT
ZIP:06902-5914
Country:US
Phone:203-708-8900
CAGE:86807

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPRIETARY INGREDIENTS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:ORAL LD50 (HUMAN): 5 G/KG
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGESTION: VERY LOW TOXICITY, CNS
    DEPRESSION IN CHILDREN AT DOSES OF 2-3 OUNCES. SKIN: SLIGHT
    IRRITATION. FLUID CAN BE SLOWLY ABSORBED. EYES: MILD IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, RAPID HEART/BREATHING RATE, ASTHMA
    LIKE EFFECTS.
Medical Cond Aggravated by Exposure:ASTHMA/OTHER REACTIVE AIRWAY
    DISORDERS.

=======================  First Aid Measures  =======================

First Aid:EYES: IMMEDIATELY FLUSH W/LARGE AMOUNTS OF WATER. SKIN: WASH
    OFF W/WATER. INHALATION: REMOVE TO FRESH AIR. GIVE CPR IF NEEDED.
    INGESTION: DON'T INDUCE VOMITING IF NOT FULLY CONSCIOUS. OBTAIN
    MEDICAL A TTENTION IN ALL CASES. NOTE TO PHYSICIAN: INGESTION OF
    SEVERAL OUNCES BY A CHILD COULD RESULT IN METABOLIC ACIDOSIS. TREAT
    PH IMBALANCE W/BICARBONATE. TREAT RESPIRATORY EFFECTS
    SYMPTOMATICALLY.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:NONE
Extinguishing Media:WATER FOG, ALCOHOL FOAM, DRY CHEMICAL.
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:SMALL: SOAK UP W/ABSORBENT MATERIAL & SWEEP
    INTO DRUM. LARGE: DAM TO PREVENT RUNOFF TO STORM SEWERS/WATERWAYS.
    USE VACUUM SYSTEM TO RECOVER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE REQUIRED FOR INTERMITTENT, SHORT-TERM
    EXPOSURES. WEAR ORGANIC VAPOR RESPIRATOR W/PARTICULATE FILTER IF
    NEEDED.
Ventilation:NONE REQUIRED WHERE AMBIENT INDOOR AIR QUALITY IS ADEQUATE.
Protective Gloves:NEOPRENE/RUBBER/IMPERVIOUS
Eye Protection:CHEMICAL FACE SHIELD/GOGGLES
Other Protective Equipment:NEOPRENE/RUBBER/IMPERVIOUS APRON
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
    REUSE.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212-470F
Vapor Pres:8.4
Vapor Density:2.9
Spec Gravity:1.12
Evaporation Rate & Reference:(N-BU AC = 1): 0.01
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID W/PLEASANT MILD ODOR.
Percent Volatiles by Volume:16

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS, STRONG ACIDS, PEROXIDES.
Hazardous Decomposition Products:NONE

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONTACT COMMERCIAL CHEMICAL WASTE COMPANY TO
    DISPOSE OF WASTE IAW/FEDERAL, STATE & LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.