HARRIS WELCO/THERMACOTE WELCO -- E70S-3 -- 3439-01-039-4378
=====================  Product Identification  =====================

Product ID:E70S-3
MSDS Date:07/01/1993
FSC:3439
NIIN:01-039-4378
=== Responsible Party ===
Company Name:HARRIS WELCO/THERMACOTE WELCO
Address:1051 YORK RD
City:KING MOUNTAIN
State:NC
ZIP:28086
Country:US
Info Phone Num:704-739-6421
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:JO222
=== Contractor Identification ===
Company Name:HARRIS WELCO/THERMACOTE WELCO
Address:1051 YORK RD
Box:828
City:KINGS MOUNTAIN
State:NC
ZIP:28086
Country:US
Phone:704-739-6421
CAGE:JO222
Company Name:J. W. HARRIS CO INC & HARRIS WELCO, DIVISION/J.W. HARRIS
    CO
Address:1051 YORK RD
Box:City:KINGS MOUNTAIN
State:NC
ZIP:28086
Country:US
Phone:704-739-6421
CAGE:34920

=============  Composition/Information on Ingredients  =============

Ingred Name:CARBON BLACK; (CARBON)
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: >0.5%
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3

Ingred Name:MANGANESE (SARA 313)
CAS:7439-96-5
RTECS #:OO9275000
Fraction by Wt: >2.5%
OSHA PEL:5 MG/M3 DUST, C
ACGIH TLV:5 MG/M3 DUST

Ingred Name:SILICON
CAS:7440-21-3
RTECS #:VW0400000
Fraction by Wt: >1.5%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST

Ingred Name:COPPER (SARA 313) (CERCLA)
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: >0.5%
OSHA PEL:0.1MG/M3 FUME;1 DUST
ACGIH TLV:0.2 MG/M3 FUME
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:MOLYBDENUM
CAS:7439-98-7
RTECS #:QA4680000
Fraction by Wt: >0.75%
OSHA PEL:10 PPM
ACGIH TLV:10 PPM

Ingred Name:ALUMINUM (SARA 313)
CAS:7429-90-5
RTECS #:BD0330000
Fraction by Wt: >0.5%
OSHA PEL:15 MG/M3 DUST
ACGIH TLV:10 MG/M3 DUST

Ingred Name:TITANIUM
CAS:7440-32-6
RTECS #:XR1700000
Fraction by Wt: >0.5%
ACGIH TLV:10 MG/M3 (MFR)

Ingred Name:ZIRCONIUM
CAS:7440-67-7
RTECS #:ZH7070000
Fraction by Wt: >0.5%
OSHA PEL:5 MG/M3
ACGIH TLV:5 MG/M3;10 STEL

Ingred Name:IRON
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: BALANCE
ACGIH TLV:5 MG/M3 (MFR)

Ingred Name:SUPDAT:IN ELECTRODE, ARE IMPORTANT. CONC OF GIVEN FUME/GAS
    COMPONENT MAY DECR/INCR BY MANY TIMES ORIGINAL CONC (ING 11)

Ingred Name:ING 10:IN ELECTRODE. NEW CMPDS NOT IN ELECTRODE MAY FORM.
    DECOMP PRODS OF NORMAL OPERATION INCL THOSE (ING 12)

Ingred Name:ING 11:ORIGINATING FROM VOLATILIZATION, RXN, OXIDATION OF
    INGS, PLUS THOSE FROM BASE METAL & COATING. REAS (ING 13)

Ingred Name:ING 12:EXPECTED FUME CONSTITUENTS OF PROD COULD INCL
    PRIMARILY OXIDES OF IRON; SECONDARILY COMPLEX OXIDES OF (ING 14)

Ingred Name:ING 13:MANGANESE & SILICON & ALUMINUM. GASEOUS RXN
    PRODS-CARBON MONOXIDE, CARBON DIOXIDE. OZONE & NITROGEN (ING 15)

Ingred Name:ING 14:OXIDES MAY BE FORMED BY RADIA FROM ARC & SHIELDING
    GASES WHEN EMPLOYED. ONE REC WAY TO DETERM COMPOSITION(ING 16)

Ingred Name:ING 15:& QTY OF FUMES & GASES TO WHICH WORKERS ARE EXPOS IS
    TO TAKE AIR SAMPLE FROM INSIDE WELDERS HELMET/IN (ING 17)

Ingred Name:ING 16:WORKING ZONE. SEE AWS F1.1 & AWS F1.2-1985, AVAIL
    FROM AMERICAN WELDING SOCIETY. SEE AWS PUBLICATION: (ING 18)

Ingred Name:ING 17:"FUMES & GASES IN THE WELDING ENVIRONMENT".

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ELECTRIC ARC WELDING MAY CREATE
    FOLLOWING: FUMES & GASES CAN BE DANGEROUS TO YOUR HEALTH. ARC RAYS
    CAN INJURE EYES & BURN SKIN. ELECTRIC SHOCK CAN KILL. SIGNS &
    SYMPTOMS OF EXPOSURE: SHORT TERM-DIZZIN ESS, NAUSEA, DRYNESS &
    IRRITATION OF NOSE, THROAT, EYES, CHEST TIGHTNESS, FEVER, ALLERGIC
    REACTION; (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:OVEREXPOSURE TO FUMES-SIDEROSIS
    POSSIBLE, MAY AFFECT PULMONARY FUNCTION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EMPLOY FIRST AID TECHNIQUES RECOMMENDED BY AMERICAN RED
    CROSS. INGEST:CALL MD IMMEDIATELY . EYES:IMMEDIATELY FLUSH
    W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM
    MD . SK IN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . INHAL:REMOVE
    TO FRESH AIR, OBTAIN MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:WELDING ARCS & SPARKS CAN IGNITE
    COMBUSTIBLES & FLAMMABLES. REFER TO ANSI Z49.1 FOR FIRE PREVENTION
    DURING USE OF WELDING & ALLIED PROCEDURES.

==================  Accidental Release Measures  ==================

Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Other Precautions:OTHER PRECS FOR ADDNL SAFETY INFO ON WELDING &
    CUTTING, SEE ANSI STD Z49.1-1983, SAFETY IN WELDING & CUTTING,
    WELDING HANDBOOK, VOL 1, SAFE PRACTICES IN WELDING & CUTTING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
    EXPOSURE OF CONCERN . MAKE SURE INHALED AIR DOES NOT CONTAIN FUME
    CONSTITUENTS ABOVE PERMISSIBLE EXPOSURE LEVELS.
Ventilation:MAKE SURE INHALED AIR DOES NOT CONTAIN FUME CONSTITUENTS
    ABOVE PELS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:USED. OTHER FACTORS INCL COATINGS ON METAL BEING WELDED
    (PAINT, PLATING/ GALVANIZING), NUMBER OF WELDERS & VOL OF WORK AREA
    AS PRESENCE OF CONTAMS IN ATM. WHEN ELECTRODE IS CONSUMED FU ME &
    GAS DECOMP PRODS GENERATED ARE DIFF IN PERCENT & FORM FROM INGS
    LISTED. FUME & GAS DECOMP PRODS & NOT INGS (ING 10)

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:COMPOSITION & QUALITY OF WELDING FUMES
    & GASES ARE DEPENDENT UPON METAL BEING WELDED, PROCESS & ELECTRODE
    BEING (SUPDAT)

====================  Disposal Considerations  ====================

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
    ENVIRONMENT. DISCARD PRODUCT RESIDUE, DISPOSABLE CONTAINER OR LINER
    IN AN ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE
    W/FEDERAL, STATE & LOCAL RE GULATIONS.

 ======================================================================
 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.