PCI INDUSTRIES INC -- 214 PIPE CLEANER -- 6850-01-298-3770
=====================  Product Identification  =====================

Product ID:214 PIPE CLEANER
MSDS Date:02/07/1995
FSC:6850
NIIN:01-298-3770
=== Responsible Party ===
Company Name:PCI INDUSTRIES INC
Box:9845
City:RIVIERA BEACH
State:FL
ZIP:33404
Country:US
Info Phone Num:407-844-0241
Emergency Phone Num:800-424-9300(CHEMTREC)
Preparer's Name:N. JOHNSON
CAGE:FO174
=== Contractor Identification ===
Company Name:P C I INDUSTRIES INC
Address:1661 OLD DIXIE HWY
Box:City:RIVIERA BEACH
State:FL
ZIP:33404
Country:US
Phone:305-844-0241
CAGE:0KL05
Company Name:PCI INDUSTRIES INC
Address:1661 OLD DIXIE HIGHWAY
Box:9845
City:RIVIERA BEACH
State:FL
ZIP:33419
Phone:(407) 844-0241
CAGE:FO174

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: >50%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:750PPM/1000STEL;9495
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA 313) (CERCLA)
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: <50%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/300STEL;9495
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL:CAN CAUSE RESP
    IRRIT,HEAD.SKIN/EYE:CAN CAUSE IRRIT,REDNESS,TEARING,BLURRED
    VISION,DEFATTING(DRYNESS).SKIN ABSORPTION:SEVERE IRRIT &
    DEFATTING.CAN CAUSE RASH.INGEST:CAUSES NAU,VOMIT,HEAD,DIZZ, ST
    UPOR,DIARR.POTENTIAL LOCAL/SYSTEMATIC EFFECTS DUE TO REPEATED/LONG
    TERM EXPO TO EYE/SKINS/THRU INHAL/INGEST.
Explanation of Carcinogenicity:PER MSDS:NTP/IARC/OSHA:NO.NONE HAZ
    INGREDS CONSIDERED TO BE CARCINGENITIC BY NTP/IARC/OSHA.
Effects of Overexposure:RESP IRRIT, HEADACHE, SKIN/EYE IRRIT, REDNESS,
    TEARING, BLURRED VISION, DEFATTING, DRYNESS, RASH, NAUSEA,
    VOMITING, STUPOR, DIARRHEA.
Medical Cond Aggravated by Exposure:PRE-EXISTING CONDITIONS MAY BE
    AGGRAVATED BY EXPOSURE TO THIS PRODUCT.

=======================  First Aid Measures  =======================

First Aid:EYE:IMMED FLUSH W/PLENTY OF WATER FOR @LEAST 15MINS.CALL
    PHYSICIAN. INGEST:IF CONSC DILUTE BY GIVING 2 GLASSES OF WATER.CALL
    PHYSICIAN/POIS CNTRL CNTR/HOSPITAL/EMERG RM IMMED.KEEP
    WARM/QUIET.DO NOT IN DUCE VOMIT. SKIN:REMOVE CONTAMIN CLOTH PRIOR
    TO FLUSHING W/WATER. INHAL:SEEK FRESH AIR.BREATH STOPPED GIVE ART
    RESP.GET MED ATTN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:24.0F,-4.4C
Lower Limits:1.8
Upper Limits:13.2
Extinguishing Media:FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR 800-424-9300(CHEMTREC) W/FULL FACEPIECE
    OPERATED IN PRESSURE-DEMAND OR OTHER POSITIVE PRESSURE MODE WHEN
    FIGHTING FIRES.
Unusual Fire/Explosion Hazard:VAP HEAVIER THAN AIR;MAY TRAVEL ALONG
    GROUND/MOVE BY VENTI & IGN BY PILOT
    LIGHTS/FLAMES/SPARKS/HEATER/SMOKING/ELECT MOTORS/STATIC
    DISCHARGE/OTHER IGN (SUPPLEME)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EXTINGUISH & DO NOT TURN ON ANY IGN SOURCE TIL
    AREA DETERMINED TO BE FREE OF EXPLO/FIRE HAZ.ABSORB W/SAND/INERT
    MATL.DISPOSE OF AS SOLID WASTE ACCORDING TO LOCAL, STATE AND
    FEDERAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:IMPACT MAY PUNCTURE CNTNR OR LOOSEN
    CAP CAUSING LEAK.GROUND/BOND CNTNRS WHEN POURING TO AVOID
    POSSIBILITY OF STATIC DISCHARGE SPARK.
Other Precautions:KEEP AWAY FRM HEAT/SPARK/FLAME.AVOID BREATH VAP.AVOID
    CONTACT W/EYE/CLOTH.KEEP CNTNR CLSD.USE W/ADEQUATE VENTI.CNTNR OF
    MATL MAY BE HAZ WHEN EMPTY SINCE EMPTIED CNTNR RETAIN
    RESIDUES(VAP/LIQ/&/OR SOLI D).ALL HAZ PRECAUT GIVEN MUST BE OBSERVE

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF TLV OF PRODUCT OR ANY COMPONENT OF IT IS
    EXCEEDED NIOSH/MSHA APPROVED AIR SUPPLIED RESP IS ADVISED IN
    ABSENCE OF PROPER ENVIRON CNTRL. OSHA REGS ALSO PERMIT OTHER
    NIOSH/MSHA RESP UNDER SPECIFIED CO NDITIONS.
Ventilation:PRODUCT USED IN CONFINED AREA PROVIDE SUFFI MECHANICAL(GEN
    &/OR LOC EXHAU)VENTI TO MAINTAIN EXPO BELOW TLV.EXPLO-PROOF.
Protective Gloves:RUBBER,BUTYL,OTHER IMPERVIOUS MATL.
Eye Protection:CHEMICAL SAFETY SPLASH GLASSES.
Other Protective Equipment:EYEBATH, SAFETY SHOWER, FACE SHIELD, RUBBER
    SAFETY BOOTS.
Work Hygienic Practices:WASH CONTAMIN CLOTHING BEFORE RE-USE.WASH
    THOROUGHLY AFTER USING.AVOID SKIN/EYE CONTACT.
Supplemental Safety and Health
FIRE/EXPLO HAZ:SOURCES @LOCATION DISTANT FRM MATL HNDLG PT.

==================  Physical/Chemical Properties  ==================

HCC:F2
Boiling Pt:=56.C, 132.8F
Vapor Pres:>AIR
Spec Gravity:0.8
Evaporation Rate & Reference:FASTER THAN BUTYL ACETATE
Solubility in Water:SOLUBLE.
Appearance and Odor:CLEAR LIQUID W/STRONG SOLVENT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:KEEP AWAY FROM HEAT, SPARKS, OPEN FLAME, &
    OTHER SOURCES OF IGNITION.
Hazardous Decomposition Products:MAY FORM TOXIC MATLS, CARBON DIOXIDE,
    CARBON MONOXIDE, & VARIOUS HYDROCARBONS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:COMPLY W/FED/STATE/LOCAL REGS.IF PERMITS & REGS
    ALLOW MAY BE INCINERATED.ALLOWED TO EVAPORATE OR SOLIDIFIED W/INERT
    MATL & DISPOSE OF.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.