CRC INDUSTRIES INC -- 03070 CONTACT CLEANER (AEROSOL) -- 6850-00F030783
=====================  Product Identification  =====================

Product ID:03070 CONTACT CLEANER (AEROSOL)
MSDS Date:01/01/1990
FSC:6850
NIIN:00F030783
=== Responsible Party ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Info Phone Num:215-674-4300
Emergency Phone Num:215-674-4300
Preparer's Name:ALLEN B REED
CAGE:CRCIN
=== Contractor Identification ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Phone:215-674-4300
CAGE:CRCIN

=============  Composition/Information on Ingredients  =============

Ingred Name:FREON 113, 1,1,2,-TRICHLORO-1,2,2,-TRIFLUOROETHANE,
    TRICHLOROTRIFLUROETHANE
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 75%
Other REC Limits:1000 PPM
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM
Ozone Depleting Chemical:1

Ingred Name:CHLORODIFLUOROMETHANE, FREON 22, MONOCHLORODIFLUOROMETHANE
CAS:75-45-6
RTECS #:PA6390000
Fraction by Wt: 25%
Other REC Limits:1000 PPM
OSHA PEL:1000 PPM
ACGIH TLV:3540 MG/CUM
Ozone Depleting Chemical:2

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION: CARDIAC ARRHYTHMIAS. SKIN:
    DEFATTING, DERMATITIS, IRRITATION. EYES: IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: DROWSINESS, LIGHTHEADNESS.
Medical Cond Aggravated by Exposure:IMPAIRED CARDIOVASCULAR FUNCTION
    SUCH AS CARDIAC ARRHYTHMIAS MIGHT BE SENSITIZED.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/LARGE AMOUNTS OF WATER. INHALATION: REMOVE TO
    FRESH AIR, APPLY ARTIFICIAL RESPIRATION IF NEEDED. SKIN: WASH
    W/WATER. INGESTION: INDUCE VOMITING. OBTAIN MEDICAL ATTENTION IN
    ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TOC
Flash Point:NONE
Unusual Fire/Explosion Hazard:AEROSOL CONTAINERS CAN EXPLODE IF
    CONTENTS AREA HEATED >130F.

==================  Accidental Release Measures  ==================

Spill Release Procedures:DUE TO HIGH VOLATILITY MATERIAL QUICKLY
    EVAPORATES. VENTILATE AREA, EVACUATE PERSONNEL UNTIL CONCENTRATION
    IS BELOW TLV OR USE SELF CONTAINED BREATHING APPARATUS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY AREA. STORE AT
    TEMPERATURES <130F.  VAPORS ARE VERY HEAVY & WILL COLLECT IN LOW
    AREAS.
Other Precautions:OXYGEN WOULD BE DISPLACED & ASPHYXIATION COULD
    RESULT. GOOD VENTILATION IS A MUST FOR LOW AREAS & CONFINED SPACES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:SELF CONTAINED BREATHING APPARATUS
Ventilation:AS REQUIRED
Protective Gloves:NEOPRENE
Eye Protection:SAFETY GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:117.6F
Melt/Freeze Pt:M.P/F.P Text: -35.7
Vapor Pres:5.5 PSIG
Vapor Density:6.5
Spec Gravity:1.57
Evaporation Rate & Reference:(CARBON TET = 1): 0.3
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALUMINUM, MAGNESIUM, CALCIUM, ZINC
Stability Condition to Avoid:TEMPERATURES >130F
Hazardous Decomposition Products:HALOGENS, HALOGEN ACIDS, POSSIBILITY
    OF PHOSGENE

====================  Disposal Considerations  ====================

Waste Disposal Methods:PUMP INTO DRUMS FOR RECLAMATION. DISPOSE OF IN
    ACCORDANCE W/FEDERAL, STATE & LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.